Validation of an analytical method by TLC-scanner for the determination of radiochemical purity of sodium pertechnetate 99mTc injectable solution
Validación de un método analítico por TLC-scanner para la determinación de pureza radioquímica del pertecnetato de sodio 99mTc solución inyectable
How to Cite
Download Citation
Show authors biography
Most read articles by the same author(s)
- Miguel Vásquez, Jesús Miranda, Manuel Otero, Validation of an analytical method for the determination of traces detergent in the cleaning process of a fractionation chamber of sodium iodide 131I oral solution , Informe Científico Tecnológico: Vol. 16 No. 1 (2016): ene-jun
- Miguel Vasquez, Validación del proceso de esterilización del radiofármaco Pertecnetato de Sodio Tc99m solución inyectable , Informe Científico Tecnológico: Vol. 17 No. 1 (2021): ene - dic
- Emma Castro, Alcides López, Bertha Ramos, Johnny Vargas, Mónica Vivanco, Paula Olivera, Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas , Informe Científico Tecnológico: Vol. 12 No. 1 (2012): ene-dic
- Anita Robles, Bertha Ramos, María Benites, Jorge Herrera, José Caballero, Aldo Guzmán, Síntesis y caracterización del dietilentriamino pentaacetato cálcico trisódico (DTPA - CaNa3) , Informe Científico Tecnológico: Vol. 12 No. 1 (2012): ene-dic
The validation of an analytical method was carried out for the determination of the radiochemical purity of the radiopharmaceutical Pertecnetate sodium 99mTc solution for injection, by means of thin layer chromatography (TLC) with a Radio-TLC scanner system, which allows to evaluate the quality of the product. The parameters of selectivity, linearity, precision, robustness, limit of detection, limit of quantification, range and stability were evaluated in the sample solution. Under the experimental conditions, the TLC-scanner method was statistically demonstrated to be selective for the pertechnetate band TcO - Rf of 0.9 and for the radiochemical impurity TcO2 Rf of 0.1, the linearity from 0.25 to 3.0 mCi / mL, intermediate precision with overall RSD of 0.227 %, robustness with overall RSD 0.012 %, detection limit of 0.03 % mCi / mL, limit of quantification of 0.24 mCi/mL, conformal range and stability of the sample solution evaluated at times 0, 2 and 3 hours with a global RSD of 0.196 % obtaining compliant results. In all the operations, the conformity of the tests to the acceptance criteria was verified in each of the validation stages. Under the established of our method is concluded to be suitable for use in the process of g Tc sodium pertechnetate.
Article visits 198 | PDF visits 415